[FileInfo] CreatedBy=pironex GmbH ModifiedBy=pironex GmbH Description=EnergyBus Charger CreationTime=02:37PM CreationDate=02-19-2024 ModificationTime=02:37PM ModificationDate=02-19-2024 FileName=EnergyBus_Charger.eds FileVersion=1 FileRevision=0 EDSVersion=4.0 [DeviceInfo] VendorName=pironex GmbH VendorNumber=0xffffffff ProductName=piCan-EB-Charger ProductNumber=0xffffffff RevisionNumber=0xffffffff BaudRate_10=0 BaudRate_20=0 BaudRate_50=0 BaudRate_125=0 BaudRate_250=1 BaudRate_500=0 BaudRate_800=0 BaudRate_1000=0 SimpleBootUpMaster=0 SimpleBootUpSlave=0 Granularity=8 DynamicChannelsSupported=0 CompactPDO=0 GroupMessaging=0 NrOfRXPDO=4 NrOfTXPDO=4 LSS_Supported=1 [DummyUsage] Dummy0001=0 Dummy0002=0 Dummy0003=0 Dummy0004=0 Dummy0005=0 Dummy0006=0 Dummy0007=0 [Comments] Lines=0 [MandatoryObjects] SupportedObjects=3 1=0x1000 2=0x1001 3=0x1018 [1000] ParameterName=Device Type ObjectType=0x7 DataType=0x0007 AccessType=ro PDOMapping=0 [1001] ParameterName=Error Register ObjectType=0x7 DataType=0x0005 AccessType=ro PDOMapping=0 [1018] ParameterName=Identity Object ObjectType=0x9 SubNumber=5 [1018sub0] ParameterName=Number of entries ObjectType=0x7 DataType=0x0005 AccessType=ro DefaultValue=4 PDOMapping=0 LowLimit=1 HighLimit=4 [1018sub1] ParameterName=Vendor Id ObjectType=0x7 DataType=0x0007 AccessType=ro DefaultValue=0xffffffff PDOMapping=0 [1018sub2] ParameterName=Product Code ObjectType=0x7 DataType=0x0007 AccessType=ro DefaultValue=0xffffffff PDOMapping=0 [1018sub3] ParameterName=Revision number ObjectType=0x7 DataType=0x0007 AccessType=ro DefaultValue=0xffffffff PDOMapping=0 [1018sub4] ParameterName=Serial number ObjectType=0x7 DataType=0x0007 AccessType=ro DefaultValue=0xffffffff PDOMapping=0 [OptionalObjects] SupportedObjects=62 1=0x1005 2=0x1006 3=0x1007 4=0x100A 5=0x1014 6=0x1016 7=0x1017 8=0x1200 9=0x1201 10=0x1280 11=0x1281 12=0x1282 13=0x1283 14=0x1411 15=0x1490 16=0x150F 17=0x158E 18=0x1611 19=0x1690 20=0x170F 21=0x178E 22=0x1800 23=0x1801 24=0x187F 25=0x1880 26=0x1A00 27=0x1A01 28=0x1A7F 29=0x1A80 30=0x1F51 31=0x6000 32=0x6001 33=0x6002 34=0x6003 35=0x6005 36=0x6008 37=0x6024 38=0x6025 39=0x6026 40=0x6027 41=0x603A 42=0x603B 43=0x603E 44=0x603F 45=0x6040 46=0x6042 47=0x6046 48=0x6047 49=0x604B 50=0x604E 51=0x604F 52=0x6071 53=0x60F0 54=0x60F1 55=0x60F2 56=0x60F3 57=0x60F4 58=0x60F5 59=0x60F6 60=0x60F7 61=0x60FB 62=0x60FC [1005] ParameterName=COB ID SYNC ObjectType=0x7 DataType=0x0007 AccessType=rw DefaultValue=0x80000080 PDOMapping=0 LowLimit=0x00000001 [1006] ParameterName=Communication Cycle Period ObjectType=0x7 DataType=0x0007 AccessType=rw DefaultValue=0x00000000 PDOMapping=0 [1007] ParameterName=Synchronous Window Length ObjectType=0x7 DataType=0x0007 AccessType=rw DefaultValue=0x00000000 PDOMapping=0 [100A] ParameterName=Manufacturer Software Version ObjectType=0x7 DataType=0x0009 AccessType=const PDOMapping=0 [1014] ParameterName=COB ID EMCY ObjectType=0x7 DataType=0x0007 AccessType=ro DefaultValue=$NODEID+0x80 PDOMapping=0 LowLimit=0x00000001 HighLimit=0xFFFFFFFF [1016] ParameterName=Consumer Heartbeat Time ObjectType=0x8 SubNumber=5 [1016sub0] ParameterName=Number of entries ObjectType=0x7 DataType=0x0005 AccessType=ro DefaultValue=4 PDOMapping=0 LowLimit=0x1 [1016sub1] ParameterName=Master ObjectType=0x7 DataType=0x0007 AccessType=rw DefaultValue=0 PDOMapping=0 [1016sub2] ParameterName=Battery ObjectType=0x7 DataType=0x0007 AccessType=rw DefaultValue=0 PDOMapping=0 [1016sub3] ParameterName=Battery2 ObjectType=0x7 DataType=0x0007 AccessType=rw DefaultValue=0 PDOMapping=0 [1016sub4] ParameterName=HMI ObjectType=0x7 DataType=0x0007 AccessType=rw DefaultValue=0 PDOMapping=0 [1017] ParameterName=Producer Heartbeat Time ObjectType=0x7 DataType=0x0006 AccessType=rw DefaultValue=0 PDOMapping=0 [1200] ParameterName=Server SDO Parameter 0 ObjectType=0x9 SubNumber=3 [1200sub0] ParameterName=Number of entries ObjectType=0x7 DataType=0x0005 AccessType=ro DefaultValue=2 PDOMapping=0 LowLimit=0x02 HighLimit=0x02 [1200sub1] ParameterName=COB ID Client to Server ObjectType=0x7 DataType=0x0007 AccessType=ro DefaultValue=$NODEID+0x600 PDOMapping=0 [1200sub2] ParameterName=COB ID Server to Client ObjectType=0x7 DataType=0x0007 AccessType=ro DefaultValue=$NODEID+0x580 PDOMapping=0 [1201] ParameterName=Server SDO Parameter 1 ObjectType=0x9 SubNumber=4 [1201sub0] ParameterName=Number of entries ObjectType=0x7 DataType=0x0005 AccessType=ro DefaultValue=3 PDOMapping=0 LowLimit=0x2 HighLimit=0x03 [1201sub1] ParameterName=COB ID Client to Server ObjectType=0x7 DataType=0x0007 AccessType=rw DefaultValue=0x80000000 PDOMapping=0 LowLimit=0x1 HighLimit=0xFFFFFFFF [1201sub2] ParameterName=COB ID Server to Client ObjectType=0x7 DataType=0x0007 AccessType=rw DefaultValue=0x80000000 PDOMapping=0 LowLimit=0x1 HighLimit=0xFFFFFFFF [1201sub3] ParameterName=Node ID of the SDO Client ObjectType=0x7 DataType=0x0005 AccessType=rw PDOMapping=0 LowLimit=0 HighLimit=127 [1280] ParameterName=Client SDO Parameter 0 ObjectType=0x9 SubNumber=4 [1280sub0] ParameterName=Number of entries ObjectType=0x7 DataType=0x0005 AccessType=ro DefaultValue=3 PDOMapping=0 LowLimit=0x03 HighLimit=0x03 [1280sub1] ParameterName=COB ID Client to Server ObjectType=0x7 DataType=0x0007 AccessType=rw DefaultValue=0x80000000 PDOMapping=0 LowLimit=0x1 HighLimit=0xFFFFFFFF [1280sub2] ParameterName=COB ID Server to Client ObjectType=0x7 DataType=0x0007 AccessType=rw DefaultValue=0x80000000 PDOMapping=0 LowLimit=0x1 HighLimit=0xFFFFFFFF [1280sub3] ParameterName=Node ID of the SDO Server ObjectType=0x7 DataType=0x0005 AccessType=rw PDOMapping=0 LowLimit=0 HighLimit=127 [1281] ParameterName=Client SDO Parameter 1 ObjectType=0x9 SubNumber=4 [1281sub0] ParameterName=Number of entries ObjectType=0x7 DataType=0x0005 AccessType=ro DefaultValue=3 PDOMapping=0 LowLimit=0x03 HighLimit=0x03 [1281sub1] ParameterName=COB ID Client to Server ObjectType=0x7 DataType=0x0007 AccessType=rw DefaultValue=0x80000000 PDOMapping=0 LowLimit=0x1 HighLimit=0xFFFFFFFF [1281sub2] ParameterName=COB ID Server to Client ObjectType=0x7 DataType=0x0007 AccessType=rw DefaultValue=0x80000000 PDOMapping=0 LowLimit=0x1 HighLimit=0xFFFFFFFF [1281sub3] ParameterName=Node ID of the SDO Server ObjectType=0x7 DataType=0x0005 AccessType=rw PDOMapping=0 LowLimit=0 HighLimit=127 [1282] ParameterName=Client SDO Parameter 2 ObjectType=0x9 SubNumber=4 [1282sub0] ParameterName=Number of entries ObjectType=0x7 DataType=0x0005 AccessType=ro DefaultValue=3 PDOMapping=0 LowLimit=0x03 HighLimit=0x03 [1282sub1] ParameterName=COB ID Client to Server ObjectType=0x7 DataType=0x0007 AccessType=rw DefaultValue=0x80000000 PDOMapping=0 LowLimit=0x1 HighLimit=0xFFFFFFFF [1282sub2] ParameterName=COB ID Server to Client ObjectType=0x7 DataType=0x0007 AccessType=rw DefaultValue=0x80000000 PDOMapping=0 LowLimit=0x1 HighLimit=0xFFFFFFFF [1282sub3] ParameterName=Node ID of the SDO Server ObjectType=0x7 DataType=0x0005 AccessType=rw PDOMapping=0 LowLimit=0 HighLimit=127 [1283] ParameterName=Client SDO Parameter 3 ObjectType=0x9 SubNumber=4 [1283sub0] ParameterName=Number of entries ObjectType=0x7 DataType=0x0005 AccessType=ro DefaultValue=3 PDOMapping=0 LowLimit=0x03 HighLimit=0x03 [1283sub1] ParameterName=COB ID Client to Server ObjectType=0x7 DataType=0x0007 AccessType=rw DefaultValue=0x80000000 PDOMapping=0 LowLimit=0x1 HighLimit=0xFFFFFFFF [1283sub2] ParameterName=COB ID Server to Client ObjectType=0x7 DataType=0x0007 AccessType=rw DefaultValue=0x80000000 PDOMapping=0 LowLimit=0x1 HighLimit=0xFFFFFFFF [1283sub3] ParameterName=Node ID of the SDO Server ObjectType=0x7 DataType=0x0005 AccessType=rw PDOMapping=0 LowLimit=0 HighLimit=127 [1411] ParameterName=Receive PDO Communication Parameter 11 ObjectType=0x9 SubNumber=6 [1411sub0] ParameterName=Number of entries ObjectType=0x7 DataType=0x0005 AccessType=ro DefaultValue=5 PDOMapping=0 LowLimit=0x02 HighLimit=0x05 [1411sub1] ParameterName=COB ID ObjectType=0x7 DataType=0x0007 AccessType=rw DefaultValue=0x80000192 PDOMapping=0 LowLimit=0x00000001 HighLimit=0xFFFFFFFF [1411sub2] ParameterName=Transmission Type ObjectType=0x7 DataType=0x0005 AccessType=rw PDOMapping=0 [1411sub3] ParameterName=Inhibit Time ObjectType=0x7 DataType=0x0006 AccessType=rw DefaultValue=0x0000 PDOMapping=0 [1411sub4] ParameterName=Compatibility Entry ObjectType=0x7 DataType=0x0005 AccessType=rw PDOMapping=0 [1411sub5] ParameterName=Event Timer ObjectType=0x7 DataType=0x0006 AccessType=rw DefaultValue=0 PDOMapping=0 [1490] ParameterName=Receive PDO Communication Parameter 144 ObjectType=0x9 SubNumber=6 [1490sub0] ParameterName=Number of entries ObjectType=0x7 DataType=0x0005 AccessType=ro DefaultValue=5 PDOMapping=0 LowLimit=0x02 HighLimit=0x05 [1490sub1] ParameterName=COB ID ObjectType=0x7 DataType=0x0007 AccessType=rw DefaultValue=0x80000292 PDOMapping=0 LowLimit=0x00000001 HighLimit=0xFFFFFFFF [1490sub2] ParameterName=Transmission Type ObjectType=0x7 DataType=0x0005 AccessType=rw PDOMapping=0 [1490sub3] ParameterName=Inhibit Time ObjectType=0x7 DataType=0x0006 AccessType=rw DefaultValue=0x0000 PDOMapping=0 [1490sub4] ParameterName=Compatibility Entry ObjectType=0x7 DataType=0x0005 AccessType=rw PDOMapping=0 [1490sub5] ParameterName=Event Timer ObjectType=0x7 DataType=0x0006 AccessType=rw DefaultValue=0 PDOMapping=0 [150F] ParameterName=Receive PDO Communication Parameter 271 ObjectType=0x9 SubNumber=6 [150Fsub0] ParameterName=Number of entries ObjectType=0x7 DataType=0x0005 AccessType=ro DefaultValue=5 PDOMapping=0 LowLimit=0x02 HighLimit=0x05 [150Fsub1] ParameterName=COB ID ObjectType=0x7 DataType=0x0007 AccessType=rw DefaultValue=0x80000392 PDOMapping=0 LowLimit=0x00000001 HighLimit=0xFFFFFFFF [150Fsub2] ParameterName=Transmission Type ObjectType=0x7 DataType=0x0005 AccessType=rw PDOMapping=0 [150Fsub3] ParameterName=Inhibit Time ObjectType=0x7 DataType=0x0006 AccessType=rw DefaultValue=0x0000 PDOMapping=0 [150Fsub4] ParameterName=Compatibility Entry ObjectType=0x7 DataType=0x0005 AccessType=rw PDOMapping=0 [150Fsub5] ParameterName=Event Timer ObjectType=0x7 DataType=0x0006 AccessType=rw DefaultValue=0 PDOMapping=0 [158E] ParameterName=Receive PDO Communication Parameter 398 ObjectType=0x9 SubNumber=6 [158Esub0] ParameterName=Number of entries ObjectType=0x7 DataType=0x0005 AccessType=ro DefaultValue=5 PDOMapping=0 LowLimit=0x02 HighLimit=0x05 [158Esub1] ParameterName=COB ID ObjectType=0x7 DataType=0x0007 AccessType=rw DefaultValue=0x80000492 PDOMapping=0 LowLimit=0x00000001 HighLimit=0xFFFFFFFF [158Esub2] ParameterName=Transmission Type ObjectType=0x7 DataType=0x0005 AccessType=rw PDOMapping=0 [158Esub3] ParameterName=Inhibit Time ObjectType=0x7 DataType=0x0006 AccessType=rw DefaultValue=0x0000 PDOMapping=0 [158Esub4] ParameterName=Compatibility Entry ObjectType=0x7 DataType=0x0005 AccessType=rw PDOMapping=0 [158Esub5] ParameterName=Event Timer ObjectType=0x7 DataType=0x0006 AccessType=rw DefaultValue=0 PDOMapping=0 [1611] ParameterName=Receive PDO Mapping Parameter 11 ObjectType=0x9 SubNumber=5 [1611sub0] ParameterName=Number of entries ObjectType=0x7 DataType=0x0005 AccessType=rw DefaultValue=4 PDOMapping=0 LowLimit=0 HighLimit=8 [1611sub1] ParameterName=PDO Device Status ObjectType=0x7 DataType=0x0007 AccessType=rw DefaultValue=0x25010110 PDOMapping=0 [1611sub2] ParameterName=PDO Device dynamic current input limitation ObjectType=0x7 DataType=0x0007 AccessType=rw DefaultValue=0x25010a10 PDOMapping=0 [1611sub3] ParameterName=PDO Device dynamic current output limitation ObjectType=0x7 DataType=0x0007 AccessType=rw DefaultValue=0x25010b10 PDOMapping=0 [1611sub4] ParameterName=PDO Device dynamic voltage limitation ObjectType=0x7 DataType=0x0007 AccessType=rw DefaultValue=0x25010c10 PDOMapping=0 [1690] ParameterName=Receive PDO Mapping Parameter 144 ObjectType=0x9 SubNumber=3 [1690sub0] ParameterName=Number of entries ObjectType=0x7 DataType=0x0005 AccessType=rw DefaultValue=2 PDOMapping=0 LowLimit=0 HighLimit=8 [1690sub1] ParameterName=PDO Device actual current ObjectType=0x7 DataType=0x0007 AccessType=rw DefaultValue=0x25010220 PDOMapping=0 [1690sub2] ParameterName=PDO Device actual voltage ObjectType=0x7 DataType=0x0007 AccessType=rw DefaultValue=0x25010320 PDOMapping=0 [170F] ParameterName=Receive PDO Mapping Parameter 271 ObjectType=0x9 SubNumber=4 [170Fsub0] ParameterName=Number of entries ObjectType=0x7 DataType=0x0005 AccessType=rw DefaultValue=3 PDOMapping=0 LowLimit=0 HighLimit=8 [170Fsub1] ParameterName=PDO Mapping Entry 1 ObjectType=0x7 DataType=0x0007 AccessType=rw PDOMapping=0 [170Fsub2] ParameterName=PDO Mapping Entry 2 ObjectType=0x7 DataType=0x0007 AccessType=rw DefaultValue=0x25010710 PDOMapping=0 [170Fsub3] ParameterName=PDO Mapping Entry 3 ObjectType=0x7 DataType=0x0007 AccessType=rw PDOMapping=0 [178E] ParameterName=Receive PDO Mapping Parameter 398 ObjectType=0x9 SubNumber=9 [178Esub0] ParameterName=Number of entries ObjectType=0x7 DataType=0x0005 AccessType=rw DefaultValue=8 PDOMapping=0 LowLimit=0 HighLimit=8 [178Esub1] ParameterName=PDO Mapping Entry 1 ObjectType=0x7 DataType=0x0007 AccessType=rw PDOMapping=0 [178Esub2] ParameterName=PDO Mapping Entry 2 ObjectType=0x7 DataType=0x0007 AccessType=rw PDOMapping=0 [178Esub3] ParameterName=PDO Mapping Entry 3 ObjectType=0x7 DataType=0x0007 AccessType=rw PDOMapping=0 [178Esub4] ParameterName=PDO Mapping Entry 4 ObjectType=0x7 DataType=0x0007 AccessType=rw PDOMapping=0 [178Esub5] ParameterName=PDO Mapping Entry 5 ObjectType=0x7 DataType=0x0007 AccessType=rw PDOMapping=0 [178Esub6] ParameterName=PDO Mapping Entry 6 ObjectType=0x7 DataType=0x0007 AccessType=rw PDOMapping=0 [178Esub7] ParameterName=PDO Mapping Entry 7 ObjectType=0x7 DataType=0x0007 AccessType=rw PDOMapping=0 [178Esub8] ParameterName=PDO Mapping Entry_8 ObjectType=0x7 DataType=0x0007 AccessType=rw PDOMapping=0 [1800] ParameterName=Transmit PDO Communication Parameter 0 ObjectType=0x9 SubNumber=6 [1800sub0] ParameterName=Number of entries ObjectType=0x7 DataType=0x0005 AccessType=ro DefaultValue=5 PDOMapping=0 LowLimit=0x02 HighLimit=0x06 [1800sub1] ParameterName=COB ID ObjectType=0x7 DataType=0x0007 AccessType=rw DefaultValue=0x80000181 PDOMapping=0 LowLimit=0x00000001 HighLimit=0xFFFFFFFF [1800sub2] ParameterName=Transmission Type ObjectType=0x7 DataType=0x0005 AccessType=rw DefaultValue=0xff PDOMapping=0 [1800sub3] ParameterName=Inhibit Time ObjectType=0x7 DataType=0x0006 AccessType=rw DefaultValue=0x0000 PDOMapping=0 [1800sub4] ParameterName=Compatibility Entry ObjectType=0x7 DataType=0x0005 AccessType=rw DefaultValue=0 PDOMapping=0 [1800sub5] ParameterName=Event Timer ObjectType=0x7 DataType=0x0006 AccessType=rw DefaultValue=0 PDOMapping=0 [1801] ParameterName=Transmit PDO Communication Parameter 1 ObjectType=0x9 SubNumber=6 [1801sub0] ParameterName=Number of entries ObjectType=0x7 DataType=0x0005 AccessType=ro DefaultValue=5 PDOMapping=0 LowLimit=0x02 HighLimit=0x06 [1801sub1] ParameterName=COB ID ObjectType=0x7 DataType=0x0007 AccessType=rw DefaultValue=0x182 PDOMapping=0 LowLimit=0x00000001 HighLimit=0xFFFFFFFF [1801sub2] ParameterName=Transmission Type ObjectType=0x7 DataType=0x0005 AccessType=rw DefaultValue=0xff PDOMapping=0 [1801sub3] ParameterName=Inhibit Time ObjectType=0x7 DataType=0x0006 AccessType=rw DefaultValue=0x0000 PDOMapping=0 [1801sub4] ParameterName=Compatibility Entry ObjectType=0x7 DataType=0x0005 AccessType=rw PDOMapping=0 [1801sub5] ParameterName=Event Timer ObjectType=0x7 DataType=0x0006 AccessType=rw DefaultValue=0 PDOMapping=0 [187F] ParameterName=Transmit PDO Communication Parameter 127 ObjectType=0x9 SubNumber=6 [187Fsub0] ParameterName=Number of entries ObjectType=0x7 DataType=0x0005 AccessType=ro DefaultValue=5 PDOMapping=0 LowLimit=0x02 HighLimit=0x06 [187Fsub1] ParameterName=COB ID ObjectType=0x7 DataType=0x0007 AccessType=rw DefaultValue=0x80000281 PDOMapping=0 LowLimit=0x00000001 HighLimit=0xFFFFFFFF [187Fsub2] ParameterName=Transmission Type ObjectType=0x7 DataType=0x0005 AccessType=rw DefaultValue=0xff PDOMapping=0 [187Fsub3] ParameterName=Inhibit Time ObjectType=0x7 DataType=0x0006 AccessType=rw DefaultValue=0x0000 PDOMapping=0 [187Fsub4] ParameterName=Compatibility Entry ObjectType=0x7 DataType=0x0005 AccessType=rw PDOMapping=0 [187Fsub5] ParameterName=Event Timer ObjectType=0x7 DataType=0x0006 AccessType=rw DefaultValue=0 PDOMapping=0 [1880] ParameterName=Transmit PDO Communication Parameter 128 ObjectType=0x9 SubNumber=6 [1880sub0] ParameterName=Number of entries ObjectType=0x7 DataType=0x0005 AccessType=ro DefaultValue=5 PDOMapping=0 LowLimit=0x02 HighLimit=0x06 [1880sub1] ParameterName=COB ID ObjectType=0x7 DataType=0x0007 AccessType=rw DefaultValue=0x282 PDOMapping=0 LowLimit=0x00000001 HighLimit=0xFFFFFFFF [1880sub2] ParameterName=Transmission Type ObjectType=0x7 DataType=0x0005 AccessType=rw DefaultValue=0xff PDOMapping=0 [1880sub3] ParameterName=Inhibit Time ObjectType=0x7 DataType=0x0006 AccessType=rw DefaultValue=0x0000 PDOMapping=0 [1880sub4] ParameterName=Compatibility Entry ObjectType=0x7 DataType=0x0005 AccessType=rw PDOMapping=0 [1880sub5] ParameterName=Event Timer ObjectType=0x7 DataType=0x0006 AccessType=rw DefaultValue=0 PDOMapping=0 [1A00] ParameterName=Transmit PDO Mapping Parameter 0 ObjectType=0x9 SubNumber=5 [1A00sub0] ParameterName=Number of entries ObjectType=0x7 DataType=0x0005 AccessType=rw DefaultValue=4 PDOMapping=0 LowLimit=0 HighLimit=8 [1A00sub1] ParameterName=PDO Mapping Entry_1 ObjectType=0x7 DataType=0x0007 AccessType=rw DefaultValue=0x60020110 PDOMapping=0 [1A00sub2] ParameterName=PDO Mapping Entry_2 ObjectType=0x7 DataType=0x0007 AccessType=rw DefaultValue=0x60220110 PDOMapping=0 [1A00sub3] ParameterName=PDO Mapping Entry_3 ObjectType=0x7 DataType=0x0007 AccessType=rw DefaultValue=0x60230110 PDOMapping=0 [1A00sub4] ParameterName=PDO Mapping Entry_4 ObjectType=0x7 DataType=0x0007 AccessType=rw DefaultValue=0x60200110 PDOMapping=0 [1A01] ParameterName=Transmit PDO Mapping Parameter 1 ObjectType=0x9 SubNumber=5 [1A01sub0] ParameterName=Number of entries ObjectType=0x7 DataType=0x0005 AccessType=rw DefaultValue=4 PDOMapping=0 LowLimit=0 HighLimit=8 [1A01sub1] ParameterName=PDO Mapping Entry 1 ObjectType=0x7 DataType=0x0007 AccessType=rw DefaultValue=0x60020210 PDOMapping=0 [1A01sub2] ParameterName=PDO Mapping Entry 2 ObjectType=0x7 DataType=0x0007 AccessType=rw DefaultValue=0x60220210 PDOMapping=0 [1A01sub3] ParameterName=PDO Mapping Entry 3 ObjectType=0x7 DataType=0x0007 AccessType=rw DefaultValue=0x60230210 PDOMapping=0 [1A01sub4] ParameterName=PDO Mapping Entry 4 ObjectType=0x7 DataType=0x0007 AccessType=rw DefaultValue=0x60200210 PDOMapping=0 [1A7F] ParameterName=Transmit PDO Mapping Parameter 127 ObjectType=0x9 SubNumber=3 [1A7Fsub0] ParameterName=Number of entries ObjectType=0x7 DataType=0x0005 AccessType=rw DefaultValue=2 PDOMapping=0 LowLimit=0 HighLimit=8 [1A7Fsub1] ParameterName=PDO Mapping Entry 1 ObjectType=0x7 DataType=0x0007 AccessType=rw DefaultValue=0x603e0120 PDOMapping=0 [1A7Fsub2] ParameterName=PDO Mapping Entry 2 ObjectType=0x7 DataType=0x0007 AccessType=rw DefaultValue=0x60400120 PDOMapping=0 [1A80] ParameterName=Transmit PDO Mapping Parameter 128 ObjectType=0x9 SubNumber=3 [1A80sub0] ParameterName=Number of entries ObjectType=0x7 DataType=0x0005 AccessType=rw DefaultValue=2 PDOMapping=0 LowLimit=0 HighLimit=8 [1A80sub1] ParameterName=PDO Mapping Entry ObjectType=0x7 DataType=0x0007 AccessType=rw DefaultValue=0x603e0220 PDOMapping=0 [1A80sub2] ParameterName=PDO Mapping Entry_2 ObjectType=0x7 DataType=0x0007 AccessType=rw DefaultValue=0x60400220 PDOMapping=0 [1F51] ParameterName=Program Control ObjectType=0x8 SubNumber=2 [1F51sub0] ParameterName=Number of entries ObjectType=0x7 DataType=0x0005 AccessType=ro DefaultValue=1 PDOMapping=0 [1F51sub1] ParameterName=Program Control ObjectType=0x7 DataType=0x0005 AccessType=rw DefaultValue=0x00 PDOMapping=0 LowLimit=0x00 HighLimit=2 [6000] ParameterName=Supported virtual devices ObjectType=0x8 SubNumber=3 [6000sub0] ParameterName=NrOfObjects ObjectType=0x7 DataType=0x0005 AccessType=ro DefaultValue=2 PDOMapping=0 [6000sub1] ParameterName=EBC ObjectType=0x7 DataType=0x0007 AccessType=ro DefaultValue=0x01010105 PDOMapping=0 [6000sub2] ParameterName=Charger ObjectType=0x7 DataType=0x0007 AccessType=ro DefaultValue=0x01010105 PDOMapping=0 [6001] ParameterName=Control word ObjectType=0x8 SubNumber=3 [6001sub0] ParameterName=NrOfObjects ObjectType=0x7 DataType=0x0005 AccessType=ro DefaultValue=2 PDOMapping=0 [6001sub1] ParameterName=EBC ObjectType=0x7 DataType=0x0006 AccessType=rw PDOMapping=0 [6001sub2] ParameterName=Charger ObjectType=0x7 DataType=0x0006 AccessType=rw PDOMapping=0 [6002] ParameterName=Status word ObjectType=0x8 SubNumber=3 [6002sub0] ParameterName=NrOfObjects ObjectType=0x7 DataType=0x0005 AccessType=ro DefaultValue=2 PDOMapping=0 [6002sub1] ParameterName=EBC ObjectType=0x7 DataType=0x0006 AccessType=ro PDOMapping=1 [6002sub2] ParameterName=Charger ObjectType=0x7 DataType=0x0006 AccessType=ro PDOMapping=1 [6003] ParameterName=Device capability ObjectType=0x8 SubNumber=3 [6003sub0] ParameterName=NrOfObjects ObjectType=0x7 DataType=0x0005 AccessType=ro DefaultValue=2 PDOMapping=0 [6003sub1] ParameterName=EBC ObjectType=0x7 DataType=0x0006 AccessType=ro DefaultValue=0x00A7 PDOMapping=0 [6003sub2] ParameterName=Device capability2 ObjectType=0x7 DataType=0x0006 AccessType=ro DefaultValue=0x00A7 PDOMapping=0 [6005] ParameterName=Device unique part number ObjectType=0x7 DataType=0x0007 AccessType=ro PDOMapping=0 [6008] ParameterName=Device nominal voltage ObjectType=0x8 SubNumber=3 [6008sub0] ParameterName=NrOfObjects ObjectType=0x7 DataType=0x0005 AccessType=ro DefaultValue=2 PDOMapping=0 [6008sub1] ParameterName=EBC ObjectType=0x7 DataType=0x0007 AccessType=ro PDOMapping=0 [6008sub2] ParameterName=Device nominal voltage2 ObjectType=0x7 DataType=0x0007 AccessType=ro PDOMapping=0 [6024] ParameterName=Device maximum continuous input current ObjectType=0x8 SubNumber=3 [6024sub0] ParameterName=NrOfObjects ObjectType=0x7 DataType=0x0005 AccessType=ro DefaultValue=2 PDOMapping=0 [6024sub1] ParameterName=EBC ObjectType=0x7 DataType=0x0004 AccessType=ro PDOMapping=0 [6024sub2] ParameterName=Device maximum continuous input current2 ObjectType=0x7 DataType=0x0004 AccessType=ro PDOMapping=0 [6025] ParameterName=Device maximum continuous output current ObjectType=0x8 SubNumber=3 [6025sub0] ParameterName=NrOfObjects ObjectType=0x7 DataType=0x0005 AccessType=ro DefaultValue=2 PDOMapping=0 [6025sub1] ParameterName=EBC ObjectType=0x7 DataType=0x0004 AccessType=ro PDOMapping=0 [6025sub2] ParameterName=Device maximum continuous output current2 ObjectType=0x7 DataType=0x0004 AccessType=ro PDOMapping=0 [6026] ParameterName=Device maximum voltage ObjectType=0x8 SubNumber=3 [6026sub0] ParameterName=NrOfObjects ObjectType=0x7 DataType=0x0005 AccessType=ro DefaultValue=2 PDOMapping=0 [6026sub1] ParameterName=EBC ObjectType=0x7 DataType=0x0004 AccessType=ro PDOMapping=0 [6026sub2] ParameterName=Device maximum voltage2 ObjectType=0x7 DataType=0x0004 AccessType=ro PDOMapping=0 [6027] ParameterName=Device minimum voltage ObjectType=0x8 SubNumber=3 [6027sub0] ParameterName=NrOfObjects ObjectType=0x7 DataType=0x0005 AccessType=ro DefaultValue=2 PDOMapping=0 [6027sub1] ParameterName=EBC ObjectType=0x7 DataType=0x0004 AccessType=ro PDOMapping=0 [6027sub2] ParameterName=Device minimum voltage2 ObjectType=0x7 DataType=0x0004 AccessType=ro PDOMapping=0 [603A] ParameterName=Device peak input current ObjectType=0x8 SubNumber=3 [603Asub0] ParameterName=NrOfObjects ObjectType=0x7 DataType=0x0005 AccessType=ro DefaultValue=2 PDOMapping=0 [603Asub1] ParameterName=EBC ObjectType=0x7 DataType=0x0004 AccessType=ro PDOMapping=0 [603Asub2] ParameterName=Device peak input current2 ObjectType=0x7 DataType=0x0004 AccessType=ro PDOMapping=0 [603B] ParameterName=Device peak input current time ObjectType=0x8 SubNumber=3 [603Bsub0] ParameterName=NrOfObjects ObjectType=0x7 DataType=0x0005 AccessType=ro DefaultValue=2 PDOMapping=0 [603Bsub1] ParameterName=EBC ObjectType=0x7 DataType=0x0007 AccessType=ro PDOMapping=0 [603Bsub2] ParameterName=Device peak input current time2 ObjectType=0x7 DataType=0x0007 AccessType=ro PDOMapping=0 [603E] ParameterName=Device actual current ObjectType=0x8 SubNumber=3 [603Esub0] ParameterName=NrOfObjects ObjectType=0x7 DataType=0x0005 AccessType=ro DefaultValue=2 PDOMapping=0 [603Esub1] ParameterName=EBC ObjectType=0x7 DataType=0x0004 AccessType=ro PDOMapping=1 [603Esub2] ParameterName=Charger ObjectType=0x7 DataType=0x0004 AccessType=ro PDOMapping=1 [603F] ParameterName=DC-DC converter actual current side B ObjectType=0x8 SubNumber=3 [603Fsub0] ParameterName=NrOfObjects ObjectType=0x7 DataType=0x0005 AccessType=ro DefaultValue=2 PDOMapping=0 [603Fsub1] ParameterName=EBC ObjectType=0x7 DataType=0x0004 AccessType=ro PDOMapping=0 [603Fsub2] ParameterName=DC-DC converter actual current side B2 ObjectType=0x7 DataType=0x0004 AccessType=ro PDOMapping=0 [6040] ParameterName=Device actual voltage ObjectType=0x8 SubNumber=3 [6040sub0] ParameterName=NrOfObjects ObjectType=0x7 DataType=0x0005 AccessType=ro DefaultValue=2 PDOMapping=0 [6040sub1] ParameterName=EBC ObjectType=0x7 DataType=0x0004 AccessType=ro PDOMapping=1 [6040sub2] ParameterName=Charger ObjectType=0x7 DataType=0x0004 AccessType=ro PDOMapping=1 [6042] ParameterName=Device electronic temperature ObjectType=0x8 SubNumber=3 [6042sub0] ParameterName=NrOfObjects ObjectType=0x7 DataType=0x0005 AccessType=ro DefaultValue=2 PDOMapping=0 [6042sub1] ParameterName=EBC ObjectType=0x7 DataType=0x0003 AccessType=ro PDOMapping=0 [6042sub2] ParameterName=Device electronic temperature2 ObjectType=0x7 DataType=0x0003 AccessType=ro PDOMapping=0 [6046] ParameterName=Device set maximum voltage ObjectType=0x8 SubNumber=3 [6046sub0] ParameterName=NrOfObjects ObjectType=0x7 DataType=0x0005 AccessType=ro DefaultValue=2 PDOMapping=0 [6046sub1] ParameterName=EBC ObjectType=0x7 DataType=0x0004 AccessType=rw PDOMapping=0 [6046sub2] ParameterName=Device set maximum voltage2 ObjectType=0x7 DataType=0x0004 AccessType=rw PDOMapping=0 [6047] ParameterName=Device set minimum voltage ObjectType=0x8 SubNumber=3 [6047sub0] ParameterName=NrOfObjects ObjectType=0x7 DataType=0x0005 AccessType=ro DefaultValue=2 PDOMapping=0 [6047sub1] ParameterName=EBC ObjectType=0x7 DataType=0x0004 AccessType=rw PDOMapping=0 [6047sub2] ParameterName=Device set minimum voltage2 ObjectType=0x7 DataType=0x0004 AccessType=rw PDOMapping=0 [604B] ParameterName=Device set maximum continuous output current ObjectType=0x8 SubNumber=3 [604Bsub0] ParameterName=NrOfObjects ObjectType=0x7 DataType=0x0005 AccessType=ro DefaultValue=2 PDOMapping=0 [604Bsub1] ParameterName=EBC ObjectType=0x7 DataType=0x0007 AccessType=rw PDOMapping=0 [604Bsub2] ParameterName=Device set maximum continuous output current2 ObjectType=0x7 DataType=0x0007 AccessType=rw PDOMapping=0 [604E] ParameterName=Device set maximum peak output current ObjectType=0x8 SubNumber=3 [604Esub0] ParameterName=NrOfObjects ObjectType=0x7 DataType=0x0005 AccessType=ro DefaultValue=2 PDOMapping=0 [604Esub1] ParameterName=EBC ObjectType=0x7 DataType=0x0007 AccessType=rw PDOMapping=0 [604Esub2] ParameterName=Device set maximum peak output current2 ObjectType=0x7 DataType=0x0007 AccessType=rw PDOMapping=0 [604F] ParameterName=Device set maximum peak output current time ObjectType=0x8 SubNumber=3 [604Fsub0] ParameterName=NrOfObjects ObjectType=0x7 DataType=0x0005 AccessType=ro DefaultValue=2 PDOMapping=0 [604Fsub1] ParameterName=EBC ObjectType=0x7 DataType=0x0007 AccessType=rw PDOMapping=0 [604Fsub2] ParameterName=Device set maximum peak output current time2 ObjectType=0x7 DataType=0x0007 AccessType=rw PDOMapping=0 [6071] ParameterName=Device actual auxiliary voltage ObjectType=0x8 SubNumber=3 [6071sub0] ParameterName=NrOfObjects ObjectType=0x7 DataType=0x0005 AccessType=ro DefaultValue=2 PDOMapping=0 [6071sub1] ParameterName=Device actual auxiliary voltage1 ObjectType=0x7 DataType=0x0004 AccessType=ro PDOMapping=0 [6071sub2] ParameterName=Device actual auxiliary voltage2 ObjectType=0x7 DataType=0x0004 AccessType=ro PDOMapping=0 [60F0] ParameterName=Battery supported virtual device ObjectType=0x8 SubNumber=2 [60F0sub0] ParameterName=Number of Elements ObjectType=0x7 DataType=0x0005 AccessType=const DefaultValue=1 PDOMapping=0 [60F0sub1] ParameterName=Battery ObjectType=0x7 DataType=0x0007 AccessType=rw PDOMapping=0 [60F1] ParameterName=Battery NodeId ObjectType=0x8 SubNumber=2 [60F1sub0] ParameterName=NrOfObjects ObjectType=0x7 DataType=0x0005 AccessType=ro DefaultValue=1 PDOMapping=0 [60F1sub1] ParameterName=Battery NodeId1 ObjectType=0x7 DataType=0x0005 AccessType=rw PDOMapping=0 [60F2] ParameterName=Battery Alarm capacity ObjectType=0x8 SubNumber=2 [60F2sub0] ParameterName=Highest sub-index supported ObjectType=0x7 DataType=0x0005 AccessType=ro DefaultValue=1 PDOMapping=0 [60F2sub1] ParameterName=Subindex 1 ObjectType=0x7 DataType=0x0007 AccessType=rw DefaultValue=0 PDOMapping=0 [60F3] ParameterName=Battery Type ObjectType=0x8 SubNumber=2 [60F3sub0] ParameterName=Highest sub-index supported ObjectType=0x7 DataType=0x0005 AccessType=ro DefaultValue=1 PDOMapping=0 [60F3sub1] ParameterName=Subindex 1 ObjectType=0x7 DataType=0x0006 AccessType=rw DefaultValue=0 PDOMapping=0 [60F4] ParameterName=Battery rated Wh capacity ObjectType=0x8 SubNumber=2 [60F4sub0] ParameterName=Highest sub-index supported ObjectType=0x7 DataType=0x0005 AccessType=ro DefaultValue=1 PDOMapping=0 [60F4sub1] ParameterName=Subindex 1 ObjectType=0x7 DataType=0x0007 AccessType=rw DefaultValue=0 PDOMapping=0 [60F5] ParameterName=Battery device maximum voltage ObjectType=0x8 SubNumber=2 [60F5sub0] ParameterName=Highest sub-index supported ObjectType=0x7 DataType=0x0005 AccessType=ro DefaultValue=1 PDOMapping=0 [60F5sub1] ParameterName=Subindex 1 ObjectType=0x7 DataType=0x0004 AccessType=rw DefaultValue=0 PDOMapping=0 [60F6] ParameterName=Battery device minimum voltage ObjectType=0x8 SubNumber=2 [60F6sub0] ParameterName=NrOfObjects ObjectType=0x7 DataType=0x0005 AccessType=ro DefaultValue=1 PDOMapping=0 [60F6sub1] ParameterName=Battery device minimum voltage1 ObjectType=0x7 DataType=0x0004 AccessType=rw PDOMapping=0 [60F7] ParameterName=Battery maximum input current ObjectType=0x8 SubNumber=2 [60F7sub0] ParameterName=Highest sub-index supported ObjectType=0x7 DataType=0x0005 AccessType=ro DefaultValue=1 PDOMapping=0 [60F7sub1] ParameterName=Subindex 1 ObjectType=0x7 DataType=0x0004 AccessType=rw DefaultValue=0 PDOMapping=0 [60FB] ParameterName=Battery alarm status ObjectType=0x8 SubNumber=2 [60FBsub0] ParameterName=NrOfObjects ObjectType=0x7 DataType=0x0005 AccessType=ro DefaultValue=1 PDOMapping=0 [60FBsub1] ParameterName=Battery alarm status1 ObjectType=0x7 DataType=0x0007 AccessType=rw PDOMapping=0 [60FC] ParameterName=Command for Battery ObjectType=0x8 SubNumber=2 [60FCsub0] ParameterName=Highest sub-index supported ObjectType=0x7 DataType=0x0005 AccessType=ro DefaultValue=1 PDOMapping=0 [60FCsub1] ParameterName=Subindex 1 ObjectType=0x7 DataType=0x0006 AccessType=ro DefaultValue=0 PDOMapping=0 [ManufacturerObjects] SupportedObjects=5 1=0x2500 2=0x2501 3=0x2502 4=0x2503 5=0x2504 [2500] ParameterName=Battery Config ObjectType=0x9 SubNumber=11 [2500sub0] ParameterName=NrOfObjects ObjectType=0x7 DataType=0x0005 AccessType=rwr DefaultValue=10 PDOMapping=0 [2500sub1] ParameterName=TypeOfBattery ObjectType=0x7 DataType=0x0006 AccessType=rww PDOMapping=1 [2500sub2] ParameterName=Device maximum continuous input current ObjectType=0x7 DataType=0x0004 AccessType=rww PDOMapping=1 [2500sub3] ParameterName=Device maximum continuous output current ObjectType=0x7 DataType=0x0004 AccessType=rww PDOMapping=1 [2500sub4] ParameterName=Device maximum voltage ObjectType=0x7 DataType=0x0004 AccessType=rww PDOMapping=1 [2500sub5] ParameterName=Device minimum voltage ObjectType=0x7 DataType=0x0004 AccessType=rww PDOMapping=1 [2500sub6] ParameterName=Device dynamic current input limitation ObjectType=0x7 DataType=0x0006 AccessType=rww PDOMapping=1 [2500sub7] ParameterName=Device dynamic current output limitation ObjectType=0x7 DataType=0x0006 AccessType=rww PDOMapping=1 [2500sub8] ParameterName=Device dynamic voltage limitation ObjectType=0x7 DataType=0x0006 AccessType=rww PDOMapping=1 [2500sub9] ParameterName=Serial number ObjectType=0x7 DataType=0x0007 AccessType=rww PDOMapping=1 [2500subA] ParameterName=Rated Capacity ObjectType=0x7 DataType=0x0007 AccessType=rww PDOMapping=1 [2501] ParameterName=Battery Status ObjectType=0x9 SubNumber=13 [2501sub0] ParameterName=NrOfObjects ObjectType=0x7 DataType=0x0005 AccessType=rwr DefaultValue=12 PDOMapping=0 [2501sub1] ParameterName=Device Status ObjectType=0x7 DataType=0x0006 AccessType=rww PDOMapping=1 [2501sub2] ParameterName=Device actual current ObjectType=0x7 DataType=0x0004 AccessType=rww PDOMapping=1 [2501sub3] ParameterName=Device actual voltage ObjectType=0x7 DataType=0x0004 AccessType=rww PDOMapping=1 [2501sub4] ParameterName=Actual Capacity ObjectType=0x7 DataType=0x0007 AccessType=rww PDOMapping=1 [2501sub5] ParameterName=SOH ObjectType=0x7 DataType=0x0006 AccessType=rww PDOMapping=1 [2501sub6] ParameterName=Relative Capacity ObjectType=0x7 DataType=0x0007 AccessType=rww PDOMapping=1 [2501sub7] ParameterName=Temperature ObjectType=0x7 DataType=0x0003 AccessType=rww PDOMapping=1 [2501sub8] ParameterName=Device electronic temperature ObjectType=0x7 DataType=0x0006 AccessType=rww PDOMapping=1 [2501sub9] ParameterName=SoC ObjectType=0x7 DataType=0x0006 AccessType=rww PDOMapping=1 [2501subA] ParameterName=Device dynamic current input limitation ObjectType=0x7 DataType=0x0006 AccessType=rww PDOMapping=1 [2501subB] ParameterName=Device dynamic current output limitation ObjectType=0x7 DataType=0x0006 AccessType=rww PDOMapping=1 [2501subC] ParameterName=Device dynamic voltage limitation ObjectType=0x7 DataType=0x0006 AccessType=rww PDOMapping=1 [2502] ParameterName=Set Aux Control ObjectType=0x7 DataType=0x0005 AccessType=rw PDOMapping=0 [2503] ParameterName=CAN Debug ID ObjectType=0x7 DataType=0x0006 AccessType=rw DefaultValue=0 PDOMapping=0 [2504] ParameterName=HMI Config ObjectType=0x9 SubNumber=5 [2504sub0] ParameterName=NrOfObjects ObjectType=0x7 DataType=0x0005 AccessType=ro DefaultValue=4 PDOMapping=0 [2504sub1] ParameterName=Travel Time Total ObjectType=0x7 DataType=0x0007 AccessType=rww PDOMapping=0 [2504sub2] ParameterName=Travel Time Trip ObjectType=0x7 DataType=0x0006 AccessType=rww PDOMapping=0 [2504sub3] ParameterName=Route Total ObjectType=0x7 DataType=0x0007 AccessType=rww PDOMapping=0 [2504sub4] ParameterName=Route Trip ObjectType=0x7 DataType=0x0007 AccessType=rww PDOMapping=0